Electrical Characteristic of a Suspended Porcelain Insulator with a 154 kV Transmission Line
Seongho Jeon, In-hyuk Choi, Taeyong Kim, Youn-jung Lee, Ja-bin Koo, Ju-am Son, Junsin Yi
J Electr Electron Mater 2020;33(1):56-59.   Published online January 1, 2020
DOI: https://doi.org/10.4313/JKEM.2021.33.1.11
Porcelain insulators are typically exposed to surface discharge and lightning impulse in service. This study investigates the insulation characteristics of the external and internal discharges of a porcelain insulator with respect to its flashover for a 154 kV transmission line. The experiments are also conducted using a wet flashover test and an impulse test based on the external discharge and the internal penetration, to classify the flashover voltage-time curve of the porcelain insulator. When an impulse with a strength of 2,500 kV/μs was applied three times to 6.5 mm ceramic samples, electrical penetration of approximately 70% occurred. The impulse experiment confirmed that the electrical penetration inside the porcelain insulator coincided with the area where the electric field was concentrated. The wet flashover voltage test revealed that the flashover threshold voltage increases by approximately 7% after cleaning of the surface.
  • 10 View
  • 0 Download
Hardness Profiles of Porcelain Insulators by Climate Changes
Joohyun Lee, Hong-sik Kim, Joondong Kim, In-hyuk Choi
J Electr Electron Mater 2018;31(1):24-28.   Published online January 1, 2018
Insulators used in overhead transmission lines are continuously exposed to a number of mechanical and electrical stresses owing to external environmental factors, resulting in corrosion, reduction in durability, and deterioration. Widely used porcelain insulators are fabricated with cement and porcelain and are especially common in Korea. Changes in the hardness and chemical reactivity of the cement increase the leakage and fault currents and increase the possibility of flashover due to insulation breakdown. Therefore, it is important to evaluate the durability and defects of porcelain insulators. Studies on the reliability of various evaluation methods are needed to prevent accidents by accurately determining the replacement timing and potential defects in porcelain insulators. In this study, the hardness of the cement part of the porcelain insulator was measured using the Vickers hardness test and its composition was analyzed by energy dispersive spectroscopy and X-ray diffraction analysis. The performance of the insulators was compared in two different regions with varying climatic conditions. This study presents an evaluation method of the defects in porcelain insulators by measuring humidity, which can also be used to assess the reliability of the insulators.
  • 10 View
  • 0 Download
Regular Paper : The Analysis of Corona Discharge of Surface Flashover Model for Aging Diagnosis of Power Facility
Man Sik Pang, Jae Hyeong Choi, Woo Jin Kim, Young Seok Kim, Sang Hyun Kim
J Electr Electron Mater 2011;24(4):314-318.   Published online April 1, 2011
Recently, ultrasound, infrared detector, V-I characteristic, gas analysis, UV (ultra-violet rays) camera etc. is used as inspections and diagnoses of the safety of power equipment. Especially, UV camera have attracted a great deal of interest from the view point of easy judgement. UV camera is used corona discharge. One of the most important and difficult problems to be solved filer design, materials and corona discharge. This paper is studied on the temperature characteristics, UV generation and shape analysis and corona pulse count according to the electrode distance and applied voltage. Also, Corona discharge characteristics in air are analyzed using prototype UV camera of Korea. UV generation due to surface discharge of AC is higher than that of DC.
  • 8 View
  • 0 Download
Behavior of Surface Flashover Depending on Shape and Gap Distance of End Shield in Vacuum Interrupter
Jae Hun Yoon, Kee Jo Lim
J Electr Electron Mater 2010;23(2):169-173.   Published online February 1, 2010
  • 11 View
  • 0 Download
A Study on the Measurement of Footing Resistance of Transmission Towers with Overhead Grounding wires
Won Kyo Lee, Jong Kee Choi, Young Woo Lee, In Hyuk Choi, Kyung Chul Kim
J Electr Electron Mater 2010;23(1):61-64.   Published online January 1, 2010
  • 12 View
  • 0 Download
High Voltage : Assessment of Insulation Aging in 6.6 kV Class High Voltage Motor Stator Windings
J Electr Electron Mater 2006;19(11):1067-1071.   Published online November 1, 2006
  • 10 View
  • 0 Download
A Study on the Electric Performance of Porcelain Insulator with Al2O3 Addition in Transmission Line
J Electr Electron Mater 2005;18(1):96-103.   Published online January 1, 2005
  • 8 View
  • 0 Download
Characteristics of Surface Flashover in LN2
Jong Man Joung, Seung Myeong Baek, Sang Hyun Kim
J Electr Electron Mater 2003;16(1):70-76.   Published online January 1, 2003