Skip to main navigation Skip to main content
  • KIEEME

J Electr Electron Mater : Journal of Electrical and Electronic Materials

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS

Page Path

2
results for

"Three-phase transformer type superconducting fault current limiter"

Keywords

Publication year

Authors

"Three-phase transformer type superconducting fault current limiter"

Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types
Shin-won Lee, Tae-hee Han, Sung-hun Lim
J Electr Electron Mater 2023;36(6):614-619.   Published online November 1, 2023
DOI: https://doi.org/10.4313/JKEM.2023.36.6.13
The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.
  • 9 View
  • 0 Download
Analysis on Fault Current Limiting Operation of Three-Phase Transformer Type SFCL Using Double Quench
Tae-hee Han, Seok-cheol Ko, Sung-hun Lim
J Electr Electron Mater 2022;35(2):184-189.   Published online March 1, 2022
DOI: https://doi.org/10.4313/JKEM.2022.35.2.12
In this paper, the fault current limiting operations of three-phase transformer type superconducting fault current limiter (SFCL) using double quench, which consisted of E-I iron core with three legs wound by primary and secondary windings and two superconducting modules (SCMs), were analyzed according to three-phase ground fault types. To verify the effective operation of the three-phase transformer type SFCL using double quench, the test circuit for three-phase ground faults was constructed, and the fault current tests were carried out. Through analysis on the fault current test results, the different fault current limiting characteristics of three-phase transformer type SFCL using double quench from three-phase transformer type SFCL using three SCMs were discussed.
  • 5 View
  • 0 Download