전도성 고분자 PEDOT:PSS와 산화 그래핀 복합물 수소 가스 센서

맹성렬

PEDOT:PSS and Graphene Oxide Composite Hydrogen Gas Sensor

Sunglyul Maeng
J Electr Electron Mater 2018;31(2):69-73.
Published online: February 1, 2018
  • 7 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

The power law is very important in gas sensing for the determination of gas concentration. In this study, the resistance of a gas sensor based on poly (3, 4-ethylenedioxythiophene) polystyrene sulfonate+graphene oxide composite was found to exhibit a power law dependence on hydrogen concentration at 150℃. Experiments were carried out in the gas concentration range of 30~180 ppm at which the sensor showed a sensitivity of 6~9% with a response and recovery time of 30s.